AKCP-BASED ENVIRONMENTAL MONITORING · TEKNOANS
AKCP · SPECIAL-PURPOSE SENSORS

Rope Fuel Leak Sensor

The AKCP ropeFuel sensor detects leaks of gasoline, diesel, jet fuel and kerosene and helps identify the leak location.

FuelLiquid hydrocarbon detection
Location1 m / 1 ft resolution
RJ-45AKCP intelligent sensor port
LEDStatus indicator
−20 / +60 °COperating Temperature
30 mConnection cable
5 mCustom-order sensing rope
AlarmAutomatic leak notification

AKCP ropeFuel – Rope Fuel Leak Sensor

AKCP ropeFuel is a rope-style sensor designed to detect liquid hydrocarbon leaks around fuel storage tanks, fuel transfer stations and diesel generator areas.

It detects contact anywhere along the rope with fuels such as gasoline, Diesel #1, Jet A/B/5/8, JP-4/5/7 and kerosene. It connects to AKCP sensorProbe+ or securityProbe intelligent RJ-45 sensor ports.

When a leak is detected, the AKCP controller can trigger an alarm and identify the location in 1-metre or 1-foot increments. It is suitable for early detection of fuel loss at remote generator sites.

Important: In most cases, the sensor is single-use after exposure to a hydrocarbon liquid and must be replaced. Placement on conductive surfaces is not recommended.

Technical Specifications

Measurement Range
Wet or dry
Sensor Type
Open/closed contact input switch
Measurement Rate
Multiple readings per second; identifies fuel location along the rope in 1-metre or 1-foot increments
Response Time – Gasoline
Typically 2–12 minutes at 20°C, depending on type
Response Time – Diesel #1
Typically 60 minutes at 20°C
Response Time – Jet A/B/5/8
Typically 50–70 minutes at 20°C
Response Time – JP-4/5/7
Typically 15–70 minutes at 20°C
Response Time – Kerosene
Typically 47 minutes at 20°C
Single-Use Characteristic
Must be replaced after exposure to hydrocarbon liquid
Indicator
Status LED
Operating Temperature
−20°C to +60°C (source lists Fahrenheit as 4°F–140°F)
Maximum Tensile Force
Must not exceed 50 lb
Minimum Bend Radius
2 inches (50 mm)
Pressure
Loads above 20 lb (9 kg) per linear inch at 20°C may immediately trigger an alarm
Connection Interface
RJ-45 socket, UTP CAT5 cable
Maximum Communication Cable
100 ft (30 m) using CAT5/6
Package Contents
Sensing rope, non-sensing connection cable, main sensor module and 5 ft CAT5 extension cable
Sensing Rope Length
Minimum 1 m; custom lengths up to 5 m on request
Non-Sensing Cable
Standard 20 ft
Power Supply
Powered by the main controller; no additional power supply required
Automatic Detection
Full automatic detection, including disconnection alarm
Power Consumption
Typically 125 mW, 25 mA
Dimensions
56 × 55 × 33,3 mm
Mounting
DIN rail or screw mounting
Cable Diameter
Nominal 0.28 inch (7 mm)
Important Note
In most cases, replace after hydrocarbon contact; do not place on conductive surfaces
Number of Sensors
1
AKCP Technical Datasheet (PDF)