AKCP-BASED ENVIRONMENTAL MONITORING · TEKNOANS
AKCP · POWER MONITORING SENSORS

Current Transformers

AKCP split-core current transformers enable fast, safe and easy integration of electrical current measurements into monitoring systems without interrupting the power supply.

AKCP Current Transformers resmî ürün görseli
Overcurrent DetectionMonitor overcurrent conditions in electrical loads
Ground Fault DetectionSuitable for ground leakage and fault monitoring
MeteringCurrent measurement for energy and power monitoring systems
Analog / Digital CircuitsTransfer measurement data to monitoring infrastructure
Building ManagementSuitable for facility and building management applications
Split-Core DesignEasy installation without disconnecting cables or busbars
100–5000 A RangeWide choice of primary current ratings for different installations
High AccuracyReliable measurement and integration with AKCP power meters

AKCP Current Transformers

AKCP Current Transformers are designed to make the connection between a monitoring system and an electrical supply simple, fast and safe. Their split-core design allows installation without opening the existing cable or busbar circuit.

Conventional current transformers often require the primary circuit to be interrupted so cables or busbars can pass through the transformer core or connect to primary terminals. AKCP transformer cores open easily, fit around the conductor and can be installed without interrupting power. This reduces installation time and cost while improving operational safety.

Current transformers can be used for overcurrent detection, ground fault detection, metering, analog and digital circuits, and facility and building management applications.

The compact housing enables easy installation. A large internal window accommodates thick cables and busbars. Multiple sizes suit existing installations, with designs intended to provide high accuracy and reliability.

AKCP current transformers connect to AKCP power meters. Monitoring parameters and alarm thresholds can be configured through the power meter interface.

Technical Specifications

Primary Current100 A – 5000 A
Secondary Current5 A, 1 A
Standards ComplianceIEC44-1, BS7626
Maximum Voltage0,72/3 kV
Frequency50/60 Hz
Rated Burden1 VA – 30 VA
Accuracy Class0,5 / 1,0 / 3,0
Short-Time Thermal CurrentIth = 100 × In
Rated Safety FactorFS < 5

Connection: Current transformers operate with AKCP power meters; monitoring and alarm parameters are configured through the connected AKCP system interface.

AKCP Technical Datasheet (PDF)