AKCP-BASED ENVIRONMENTAL MONITORING · TEKNOANS
AKCP · POWER MONITORING SENSORS

Dry Contact Sensor

Connect external alarm panels and third-party equipment to the sensorProbe+ system. Monitor UPS, security, fire, HVAC and other dry-contact states remotely through user-configurable input/output functions.

AKCP Kuru Kontak Sensörü
Dual I/O FunctionPins can be configured as inputs or outputs
Configurable OutputSelect 0 V (Low) or 5 V (High) in software
20 mA OutputCan sink up to 20 mA when set to Low
SNMP Status LatchingCritical input status is retained until read via SNMP
Open / Closed DetectionMonitors the open or closed state of external switches
305 m CableUp to 1,000 ft with approved low-capacitance cable or UTP
Auto DetectionFull auto-sense support, including disconnection alarms
Unit-PoweredNo additional power supply required

Dry Contact Sensor

The AKCP Dry Contact Sensor provides an interface between external alarm panels and sensorProbe+. Intruder alarms, fire alarms and other third-party equipment requiring monitoring can be integrated easily into the sensorProbe+ system.

Versatile, user-configurable general-purpose I/O pins can monitor a wide range of inputs, including UPS status, security alerts, air-conditioning/HVAC conditions, door and window contacts and water intrusion.

Pins can be configured as inputs or outputs. In output mode, the level can be set to Low or High in software: Low corresponds to 0 V and High to 5 V. In the Low state, the output can sink up to 20 mA.

To prevent critical events from being missed, input switches can latch a fault state. When an input becomes critical, its state is retained until read via SNMP, ensuring that the event is reported even if the sensor returns to normal.

Open or closed states of external switches can be monitored easily. When used with third-party sensors, the device supports centralized monitoring of door/window contacts, water intrusion and other critical site conditions.

Operating Principle and Applications

The dry contact sensor brings voltage-free contact states into the AKCP monitoring infrastructure. The normal input state can be defined in software to match the alarm logic of different third-party devices.

As an input, it monitors whether an external switch is open or closed. When configured as an output, it provides a software-controlled Low/High level. This enables flexible integration in building automation and remote status monitoring.

The sensor is powered by the base unit, so no separate field power adapter is needed. It connects via RJ-45 using Cat 5 cable and can be extended up to 305 m with suitable low-capacitance cable.

Technical Specifications

Measurement / Status RangeInput: Alarm or Normal; Output: Set or Reset
Sensor TypeInput: open / closed contact switch; Output: High (5 V) / Low (GND)
Contact Voltage Range5 V pull-up dry contacts
Input Sampling RateMultiple readings per second; normal input state configurable in software
Electrical OutputCan sink up to 20 mA when set to Low
Communication CableRJ-45 sensor connection, UTP Cat 5 cable
Maximum Cable Length1,000 ft (305 m) with approved low-capacitance shielded cable or UTP
Power SupplyPowered by the control unit; no additional power supply required
Auto DetectionFull auto-sensing, including disconnection alarms
Number of Sensors1

Important Note: Dry contacts are not isolated; do not connect any voltage source. The dry contact output is not suitable for driving a relay directly.

AKCP Technical Datasheet (PDF)