AKCP-BASED ENVIRONMENTAL MONITORING · TEKNOANS
AKCP · POWER MONITORING SENSORS

Power Monitoring Sensor

Monitor electrical power parameters remotely, reduce manual power inspections and receive immediate alerts about potential issues.

AKCP Power Monitoring Sensor resmî ürün görseli
Phase VoltagesRemotely monitor phase voltages in single- and three-phase systems
Current MeasurementContinuously monitor load current to assess capacity and consumption
Power FactorMonitor power factor to evaluate the quality of energy usage
Active EnergyRecord active energy consumption and analyze historical data
Active PowerView real-time active power readings centrally
RS485 / ModbusIntegrate with the Modbus port of sensorProbe+ and securityProbe
PUE AnalysisUse for live PUE calculations with sensorProbe+ and AKCPro Server
DIN Rail MountingEasy installation with a durable housing mounted on a 35 mm DIN rail

AKCP Power Monitoring Sensor

The AKCP Power Monitoring Sensor is designed to monitor key electrical power parameters remotely, reduce the need for manual inspections and provide prompt notification of potential problems. It works with sensorProbe+ and securityProbe controllers and connects to their Modbus ports.

The sensor integrates with the controller's web interface under Power Management . Depending on the required measurements and controller model, multiple single-phase or three-phase Power Monitoring Sensors can be configured in the same system.

Collected data can be stored over time and displayed using built-in graphing tools. Power measurements can be used in live PUE calculations within sensorProbe+ and AKCPro Server to help assess data center energy efficiency.

The Power Monitoring Sensor provides IP-based monitoring of phase voltages, current, power factor, active energy and active power . Models are available for both single-phase and three-phase circuits.

The four-wire meter has a durable white plastic housing and mounts on a 35 mm DIN rail. Versions are available for 110 V or 220 V power applications. Supporting IEC 62053-21 and IEC 62053-23 standards for active and reactive energy measurement, the system enables centralized monitoring of critical electrical infrastructure.

Installation note: Electrical installations involving mains voltage must be carried out by qualified electricians familiar with applicable regulations and safety requirements.

Technical Specifications

Model
Single-Phase Meter | Three-Phase Meter | Three-Phase Meter – CT Type
Rated Voltage (Un)
230 VAC | 230/400 VAC (3~) | 230/400 VAC (3~)
Voltage Range
0,7–1,3 Un | 161/279 – 300/520 VAC (3~) | 161/279 – 300/520 VAC (3~)
Base Current (Ib)
10 A | 10 A | 1,5 A
Maximum Current
100 A | 100 A | 6 A
Operating Current Range
0.4% Ib – Imax | 0.4% Ib – Imax | 0.4% Ib – Imax
Overcurrent Withstand
30 × Imax / 0.01 sec | 30 × Imax / 0.01 sec | 30 × Imax / 0.01 sec
Internal Power Consumption
≤2 W / 10 VA | ≤2 W / 10 VA / phase | ≤2 W / 10 VA / phase
Frequency
50–60 Hz ±10% | 50–60 Hz ±10% | 50–60 Hz ±10%
Operating Temperature
Operating Humidity
≤75% | ≤75% | ≤75%
Standard
Standart
Voltage Accuracy
±0.5% | ±0.5% | ±0.5%
Current Accuracy
±0.5% | ±0.5% | ±0.5%
Frequency Accuracy
±0.2% | ±0.2% | ±0.2%
±%0,2 | ±%0,2 | ±%0,2
Communication
RS485 / Modbus | RS485 / Modbus | RS485 / Modbus
Dimensions (H × W × D)
100 × 76 × 65.5 mm | 130 × 126 × 65 mm | 130 × 126 × 65 mm
Maximum Cable Diameter
11.5 mm | — | —
Weight
0.35 kg | 0.7 kg net | 0.7 kg net

About the MODBUS Polling Interval

Setting the Modbus polling interval correctly is important. If polling is too frequent, there may not be enough time to complete all requests when many registers and multiple Power Monitoring Sensors share the same Modbus line. Choose an interval appropriate to the system size.

AKCP Technical Datasheet (PDF)