sensorProbeX+
Modular and Scalable MonitoringSuitable for installations requiring additional sensors and flexible I/O options.
Product Technical Information ↗Monitor temperature, humidity and differential pressure in vaccine and temperature-sensitive medicine storage, medical refrigerators and sterile production areas.

Monitoring environments where medicines and vaccines are stored is important for regulatory requirements and good practices. Many vaccines and medicines require storage between +2°C and +8°C, but actual requirements depend on manufacturer instructions. AKCP offers temperature and humidity sensors, easy-to-install wireless monitoring and differential pressure monitoring for sterile areas.
A probe placed in the air inside a medical refrigerator can show brief fluctuations when the door opens. A probe in a glycol-filled vial responds more slowly and better represents the temperature behavior of stored pharmaceutical liquids.
MEDICAL REFRIGERATOR · GLYCOL PROBE
Opening the refrigerator door or compressor cycling can cause abrupt changes in an air probe. A glycol probe dampens these fluctuations and helps reduce unnecessary alarms. AKCP NIST2 and NIST3 wireless sensors are available with a glycol-vial connection option.
NIST-TRACEABLE CALIBRATION

NIST3 sensors use three temperature elements. While the primary pair is checked for calibration consistency, the third can serve as a backup if the pair becomes unsuitable. This approach helps monitor the sensor's measurement integrity.
STERILE AREAS

Pressure monitoring can be assessed alongside temperature and humidity to strengthen the facility's environmental monitoring approach. Thresholds and validation must follow the facility's process and quality requirements.
WIRELESS MONITORING

Measurement intervals, communication coverage and notification options should be planned according to the sensor and controller specifications.
RECORDS AND OPERATIONS

AKCP monitoring systems can consolidate sensor readings and events to support operations teams.
Measurement frequency, communication coverage and notification options should be planned according to the sensor and controller specifications.

What is the purpose of a glycol vial?
It approximately represents the thermal behavior of liquid medicine, reducing the impact of sudden air fluctuations caused by door openings and compressor cycles.

Why measure differential pressure in sterile areas?
Source:
. Technical information on this page has been adapted into English with additional explanations and examples.
Pressure differences between rooms influence airflow direction. Monitoring helps manage controlled-area conditions and contamination risks.
Kaynak: AKCP Pharmaceutical and Laboratory. Technical information on this page has been adapted into English with additional explanations and examples.




















































































Global brands selected from the shared reference archive; these are not a list of Teknoans direct customers.View All References ↗
The following product families may be considered for this solution. Final selection depends on measurement points, sensor count, cable routing, communications and alarm requirements.

Suitable for installations requiring additional sensors and flexible I/O options.
Product Technical Information ↗
Monitors temperatures at different rack heights to help identify hot spots and airflow problems.
Product Technical Information ↗
Helps detect leaks under raised floors, around cooling units and in areas at risk of water ingress.
Product Technical Information ↗
Used to incorporate electrical measurements into the monitoring system when suitably configured.
Product Technical Information ↗Product photographs and technical details are sourced from official AKCP product pages. Compatibility, options and licenses should be verified before deployment.
Share your project and technical requirements.