Quicklime DCIM
Manage your data center sensors, intelligent PDUs, UPS units and backup power systems through one interface. Combine real-time monitoring, a digital twin, capacity planning, asset tracking and 2D/3D visualization.

What Can You Do with Quicklime?
Explore Quicklime's core capabilities in the sections below.
Monitoring and Alarm Management
Monitor AKCP sensors, intelligent PDUs, UPS units and third-party systems in one interface.
Details ↓Capacity Planning
Plan suitable equipment placement based on rack space, power, cooling and weight constraints.
Details ↓Thermal Risk Monitoring
Monitor hot spots and rack thermal conditions while considering ASHRAE recommendations.
Details ↓Energy Efficiency
Assess overcooled areas, unused cooling capacity and energy use.
Details ↓Real-Time Insights
PUE, ΔT, ΔP, temperature, humidity, security, power and asset data, with 2D/3D heat maps.
Details ↓2D / 3D Visualization
Detailed visualization from global and site views down to rooms, racks and individual assets.
Details ↓Browser-Based Access
Access through a web browser on Windows, Linux, laptops and smartphones.
Details ↓sensorCFD and Sensor Integration
CFD analysis informed by real sensor measurements and integrated AKCP sensor monitoring.
Details ↓Monitoring and alarm management
Monitor AKCP devices, intelligent PDUs and UPS systems in a single interface. Integrate third-party equipment through Quicklime Virtual Sensors using SNMP monitoring. Server load, uptime, power and environmental data can support live PUE calculations.
Centralized dashboards and sensor associations for monitoring and alarm management.

Capacity planning
Evaluate available rack space, power, cooling capacity and weight limits together. The Capacity AI tools described in the product documentation can suggest rack placements that meet specified requirements.
Assess where new equipment can be installed.

Thermal risk monitoring
Monitor rack hot spots and identify the risks that high temperatures pose to IT equipment. Consider ASHRAE recommendations when managing data center temperatures.
Rack-level temperature and hot-spot monitoring.

Energy efficiency and stranded capacity
Identify overcooled or underutilized areas. Compare cooling capacity with IT loads to uncover stranded capacity and support decisions to reduce energy consumption and operating costs.
Assess cooling utilization and available capacity.

Real-time insights
Monitor performance indicators such as PUE alongside live temperature, humidity, security, power, ΔT and ΔP readings. Use 2D and 3D heat maps to assess their spatial distribution.
Live dashboards, measurements and performance analytics.

2D and 3D data center visualization
Navigate from a global view to individual sites, data center rooms, racks and assets. View assets together with associated sensors in the digital twin. The product documentation also describes network cabling and power-path mapping.
A digital-twin approach for facilities, racks and assets.

Platform-independent web access
Access Quicklime through a web browser on laptops, smartphones, Windows or Linux computers. No separate client application is required; AKCP recommends Google Chrome.
Centralized browser-based access.

sensorCFD and AKCP sensors
The sensorCFD add-on for Quicklime enhances conventional CFD airflow and performance modeling with real AKCP sensor data. The product documentation also describes AI-assisted analysis and improvement recommendations based on sensor-informed CFD models.
Airflow and thermal performance analysis informed by sensor data.

Extended DCIM capabilities
Asset and network cable mapping
Place assets in racks and associate them with sensors; map network switch and port connections, cable routes, lengths and labels.
Power path mapping
Track power loads, PUE and energy usage using AKCP power meters, third-party meters and intelligent PDU data.
High availability and scalability
The product documentation describes a Kubernetes-based Linux cluster, fault tolerance, redundancy, automatic scaling and on-premises or cloud deployment.
Video AI
The product documentation describes associating video streams with sensor events, event-based notifications and AI-assisted analysis of certain conditions.
Integration protocols
According to the product documentation, data integration from SNMP, Modbus, MQTTS and BACnet sources is supported. Availability depends on installation and configuration.
Data center digital twin
Create an integrated facility view combining physical assets, rack maps and real sensor measurements.
Technical Specifications and Software Capabilities
Quicklime technical capabilities and software features. Unspecified numerical values have not been estimated.
| Product type | Data Center Infrastructure Management (DCIM) software |
|---|---|
| Monitoring scope | AKCP sensors, intelligent PDUs, UPS / backup power, servers and third-party device data |
| Connectivity and integration | SNMP; Modbus, MQTTS and BACnet integration described in product documentation |
| Dashboards and analytics | PUE, temperature, humidity, power, security, ΔT, ΔP and 2D/3D heat maps |
| Visualization | 2D / 3D facility views; global, site, room, rack and asset levels |
| Capacity management | Rack space, power, cooling, weight loads and stranded capacity analysis |
| Thermal optimization | Thermal risk monitoring; sensorCFD and sensor-assisted CFD analysis |
| Asset management | Asset placement, sensor associations and rack maps |
| Network / power infrastructure | Network cable and power-path mapping (described in product documentation) |
| Video analytics | Video AI and event-based video analysis (described in product documentation) |
| Client access | Web browser; laptops, phones, Windows and Linux |
| Recommended browser | Google Chrome (recommended by AKCP) |
| Server architecture | Kubernetes Linux cluster and high-availability architecture described in product documentation |
| Deployment | On-premises or cloud environment (per product documentation) |
| Licensing / capacity limits | Exact licensing and monitoring-point limits are not specified in the product information; verify for each project |
| Minimum hardware / operating system | Exact minimum server requirements are not provided; confirm with AKCP |
