Monitor up to five dry contact inputs through a single RJ-45 sensor port. Integrate UPS, security, air conditioning and other alarm/normal contact states into the AKCP monitoring platform.
5 Dry Contact InputsFive separate inputs on one RJ-45 sensor port
Input TypeOpen / closed contact switch; input only
RJ-45 ConnectionConnects to the AKCP sensor port using UTP Cat 5 cable
305 m CableUp to 1,000 ft with approved low-capacitance cable or UTP
Controller-PoweredNo additional power supply required
DIN Rail / Screw MountingEasy DIN-rail or screw mounting
SNMP MonitoringSNMPget polling and SNMP traps for critical states
Alarm NotificationsAlarm description and location can be sent by email or SNMP trap
5 Dry Contact Inputs (SP1+ / SP2+)
The AKCP 5 Dry Contact Inputs (5DCS) sensor monitors five independent dry contact states through a single RJ-45 sensor port. Each input is tracked as ALARM or NORMAL in software. On SP2+, the relevant port license may be required. The 5DCS supports inputs only; use the AKCP single dry contact cable (DCS15) when a sensor port must support input/output functionality.
Dry contact inputs are user-configurable and can monitor a wide range of contact outputs, including UPS status, security systems, and operating or alarm states of HVAC equipment.
Alarm and normal states can be monitored over SNMP. When a sensor enters a critical state, it can send an SNMP trap and can be queried using SNMPget. Browser-based monitoring is also supported. Alarm descriptions and fault locations can be delivered by email or SNMP trap.
Video could not be started. Please try again.
Technical Specifications
Measurement / Status Range
Alarm veya Normal
Sensor Type
Open / closed contact switch (input only)
Contact Voltage Range
5 V pull-up kuru kontaklar
Sampling Rate
Multiple readings per second; normal input state is software-configurable
Communication Cable
RJ-45 sensor connection using UTP Cat 5 cable
Maximum Cable Length
1,000 ft (305 m) with approved low-capacitance shielded cable or UTP
Power Supply
Powered by the controller; no additional power supply required
Dimensions
56 × 55 × 33,3 mm
Mounting
DIN-rail or screw mounting
Kuru Contact Kapasitesi
5 inputs per RJ-45; up to 10 dry contact inputs with sensorProbe2 and 20 with sensorProbe2+
Number of Sensors
5
Important Notice
Dry contacts are not isolated; do not connect any voltage source.
Note:5DCS connections are input-only. On SP2+, an additional license per port may be required to enable this feature.