Isolated DC Voltage Sensor

Safely measure DC voltages from -60 VDC to +60 VDC through an isolated input, and integrate third-party sensors into AKCP sensorProbe+ and securityProbe systems.

AKCP iDCV00 İzole DC Gerilim Sensörü
±60 VDC MeasurementSelectable ±0–60 VDC measurement range
±5 VDC Precision Range0.001 V resolution for low-voltage measurements
1600 VDC IsolationSafe measurement with isolated grounding
SNMP IntegrationSNMP GET, traps and alarm/normal state monitoring
Email AlertsEmail notifications at configurable thresholds
Custom Sensor IntegrationPressure, solar, battery and laboratory equipment
RJ-45 ConnectionConnects to an AKCP controller using UTP CAT5e/6
DIN Rail / Screw MountingEasy installation on a DIN rail or with screws

Isolated DC Voltage Sensor

The AKCP Isolated Digital Voltmeter integrates custom or third-party sensors with sensorProbe+ or securityProbe controllers while retaining the monitoring and alarm capabilities of standard AKCP sensors. It supports SNMP integration, email alerts based on user-configurable limits and thresholds, and SNMP trap generation.

A wide range of systems, including pressure transducers, solar monitoring equipment, battery monitors and laboratory test equipment, can be connected to AKCP infrastructure. OEM manufacturers and engineers can build custom data acquisition systems. The sensor operates in the -60 to 0 V or 0 to 60 V DC range and provides real-time measurement data.

Isolated grounding improves protection against overvoltage and short circuits. Readings can be displayed as absolute values or as percentages of full scale. Upper and lower full-scale voltage limits are user-programmable. Isolation also enables measurements at different points in a system, such as measuring individual battery voltages in a series-connected battery bank.

The web interface is designed to simplify use with external sensors. Users can enter a custom unit label, such as “lbs” for pressure, and set decimal thresholds, such as 12.8 V or 75.7 lbs.

Technical Specifications

Voltage InputSelectable ±0–60 VDC or ±0–5 VDC
Resolution / Accuracy0.001 V resolution; 1% full-scale accuracy
Status IndicatorsLED indicators for power, status and overvoltage
Input Impedance1.6 MΩ at the 60 V high range; 1.1 MΩ at the 5 V low range
Isolation Voltage1600 VDC
2-pin Phoenix connector for voltage measurement and a voltage-range selector switchInputs
ComponentsLow-power, highly integrated surface-mount technology for long-term reliability
Operating Temperature-35 °C – +80 °C
Operating Humidity20–80% RH, non-condensing
CommunicationRJ-45; UTP CAT5e/6 cable
Power SupplyPowered by the controller; no additional power supply required
Power ConsumptionTypically 110 mW, 22 mA
Maximum Cable Length60 ft / 18 m with standard CAT5/6 LAN cable
Dimensions65 (W) × 62 (H) × 15 (D) mm
MountingDIN rail or screw mounting
Number of Sensors1
AKCP Technical Datasheet (PDF)