sensorProbeX+
Modular and Scalable MonitoringSuitable for installations requiring additional sensors and flexible I/O options.
Product Technical Information ↗Centrally monitor UPS performance, battery voltage, current and terminal temperature through sensors and SNMP/Modbus integration.

AKCP combines physical sensors with SNMP or Modbus data from compatible third-party equipment. Monitor locally with sensorProbe+ or centrally across multiple sites with Quicklime DCIM.
A developing battery fault may go unnoticed while a UPS still appears online. Room temperature alone cannot reveal a hot battery terminal. Combining UPS load, battery and bypass status with local sensor measurements provides a clearer picture.

AKCP Battery Health Sensor measures voltage, current and terminal temperature in compatible batteries and DC systems. Configurable voltage input ranges support up to 60 VDC, with current measured through a suitable external transformer.

AKCP Battery Terminal Temperature Sensor attaches to the battery's negative terminal and complements room temperature readings. Its historical measurements can help identify abnormal heating.

AKCP Isolated DC Voltage Sensor provides isolated measurements within its rated input limits. Existing battery monitoring systems can also supply measurements through supported interfaces.

Compatible UPS network cards expose readings and status through SNMP OIDs. Supported sensorProbe+ controllers can use SNMP GET virtual sensors, or the equipment can be integrated with central monitoring.

Supported registers from UPS units, battery monitoring systems and power meters can be read over Modbus TCP via Ethernet or Modbus RTU via RS485. Confirm controller and device compatibility.

Voltage-free UPS alarm contacts can be connected to suitable AKCP dry-contact inputs for common fault or battery-operation status. Compatible external transmitters and alarm panels can also be integrated.

Monitor temperature, humidity, cooling-water leaks and equipment alarm contacts around UPS and battery cabinets. Suitable third-party hydrogen detectors may be required in lead-acid battery rooms according to safety design.

AKCP sensors can monitor battery voltage, current and terminal temperature. Compatible UPS interfaces provide load, operating status and available runtime data. Confirm supported measurements for each device.
Readings can be displayed in charts, reports and threshold alarms. Monitoring does not replace battery-room fire/gas protection or manufacturer BMS safety functions.




















































































Global brands selected from the shared reference archive; they are not a list of Teknoans direct customers.View All References ↗
The following product families may be considered. Final selection depends on measurement points, sensor counts, cable routes, communication and alarm requirements.

Suitable for installations requiring additional sensors and flexible I/O options.
Product Technical Information ↗
Monitors temperatures at different rack heights to help identify hot spots and airflow problems.
Product Technical Information ↗
Helps detect leaks beneath raised floors, around cooling equipment and in areas exposed to water risks.
Product Technical Information ↗
Integrates electrical measurements into the monitoring architecture when appropriately configured.
Product Technical Information ↗Product photographs and technical details come from official AKCP product pages. Verify compatibility, options and licensing before deployment.
Share your project and technical requirements.