AKCP-BASED ENVIRONMENTAL MONITORING · TEKNOANS
AKCP · POWER MONITORING SENSORS

Contactless Current Meter

Monitor multicore power cables up to 32 A without cutting the cable or separating its conductors. Installation requires neither an electrician nor system downtime.

AKCP Contactless Current Meter CCM resmî ürün görseli
Contactless MeasurementMonitor current without cutting multicore cables
Up to 32 AMonitoring of multicore power cables
Installation Without DowntimeNo system shutdown required during installation
±5% AccuracyOn factory-calibrated cables of the same type
PUE CalculationsData for energy efficiency analysis
Rack-Level MonitoringTrack IT rack current consumption
AKCP IntegrationUse with Thermal Map, Quicklime and sensorCFD
Capacity PlanningDetect loads approaching circuit-breaker limits

Monitor Current Without Cutting Cables

Conventional current transformers generally require access to a single live conductor. This is impractical for multicore cables containing phase, neutral and earth conductors within one outer sheath. The AKCP Contactless Current Meter (CCM) measures current without separating conductors or modifying the power cable.

The CCM can monitor current in two- or three-core cables and, when a reference voltage is available, can also monitor power. AKCP contactless current measurement technology makes it easier and more cost-effective to monitor current and power consumption for individual IT racks.

Accuracy is ±5% when factory-calibrated for the same cable type and ±10% for cables calibrated in the field. This supports data center capacity planning, monitoring of available power headroom, warnings as circuit breakers approach their trip thresholds and input data for PUE calculations.

The Contactless Current Meter can be used with rack Thermal Map sensors. Quicklime Server combines current load, thermal mapping and differential air pressure data to analyze rack and data center performance.

Technical Specifications

Status IndicatorPower LED and an LED array for calibration
Input / Measurement MethodMeasures current in multicore cables through magnetic-field sensing
Accuracy±5% with factory calibration on the same cable type; ±10% when calibrated outside the factory
ComponentsHighly integrated, low-power surface-mount technology for long-term reliability
Operating EnvironmentTemperature: −35°C to +80°C; humidity: 20–80%, non-condensing
Communication CableRJ-45 sensor connection; UTP Cat 5e cable
Power SupplyPowered by the control unit; no additional power supply required
Power ConsumptionTypically 7.25 mW; 1.45 mA
Maximum Cable Length50 ft (approximately 15 m) with standard CAT5/6 UTP cable
Dimensions49 (W) × 45 (H) × 51 (D) mm
MountingCable-mounted
Number of Sensors1