sensorProbeX+
Modular and Scalable MonitoringSuitable for installations requiring additional sensors and flexible I/O options.
Product Technical Information ↗Centrally track vaccine temperature history and handover points from production and shipping to cold storage and healthcare facilities.

Storage conditions for medicines and vaccines depend on product specifications. Many vaccines require +2°C to +8°C; some mRNA vaccines may require ultra-low temperatures down to −90°C. Appropriate sensors, calibration and data logging help identify temperature excursions early and preserve the chain-of-custody history.
This demonstration uses sample temperatures and handover data. Actual acceptable ranges must follow the manufacturer's instructions.

AKCP Component:
Sample data must not be used to decide whether a medical product is suitable for use. Temperature excursions must be assessed using manufacturer procedures and by the authorized quality team.
AKCP Wireless Tunnel temperature sensors support reliable measurements with application-appropriate NIST-traceable calibration and, depending on model, internal calibration checks. Suitable models may provide redundant measurements and failover functionality.
Sensors can be placed in shipment packaging, warehouses or medical refrigerators to record temperature. Correct placement to represent product temperature and verification of calibration status are essential.

Temperature data can continue to be recorded in refrigerated vehicles, while live monitoring is available when suitable network connectivity is configured. Optional GPS can associate temperature events with shipment locations.
Preserving timestamps, temperature history and shipment identity at each handover between manufacturer, carrier and receiving facility helps investigate excursions.

Wireless Tunnel servers can be positioned at suitable warehouse locations to collect sensor records. Temperatures recorded at entry and exit can be linked to product and batch identities during handover.
Measurement timestamps, temperature limits and continuity of records help assess potential excursions and periods of missing data.

Medical refrigerator temperatures and thresholds are monitored. Shipment, carton and vial identities can be linked so the relevant cold-chain history can be reviewed before administration.
This does not imply that every vial has its own sensor; a vial may be linked to the records of its shipment or storage environment.

Wireless Tunnel sensors can record data locally. When a sensor comes within range of an AKCP sensorProbe+ Wireless Tunnel Server (SP-WTS), records can synchronize and be forwarded to the AKCPro Pharma-Mon server.
SP-WTS can use Wi-Fi, Ethernet or cellular data with suitable configuration. Continuous live visibility during transport requires a configured data connection.

AKCPro Pharma-Mon associates temperature history with shipment, carton and vial identities to support investigations at handover points. Batch readings can be reviewed together with connectivity and synchronization status.
Records across the cold chain provide operations and quality teams with a traceable history for delivery, storage and pre-administration review.

No. Many vaccines are stored in this range, but requirements vary by product. Some mRNA-based products may require temperatures down to −90°C. Follow the manufacturer's instructions.
Suitable AKCP Wireless Tunnel data loggers can retain readings locally and synchronize when they reconnect to a gateway. Capacity and duration depend on the model.
No. Vial records can be associated with the measurement history of the relevant shipment or storage environment.
Monitoring software alone cannot make that decision. Manufacturer stability data, quality procedures and assessment by authorized healthcare or quality staff are required.
Source: AKCP Vaccine Transport and Storage Monitoring. Technical content has been adapted into English.




















































































Global brands selected from the shared reference archive; these are not a list of Teknoans direct customers.View All References ↗
The following product families may be considered for this solution. Final selection depends on measurement points, sensor count, cable routing, communications and alarm requirements.

Suitable for installations requiring additional sensors and flexible I/O options.
Product Technical Information ↗
Monitors temperatures at different rack heights to help identify hot spots and airflow problems.
Product Technical Information ↗
Helps detect leaks under raised floors, around cooling units and in areas at risk of water ingress.
Product Technical Information ↗
Used to incorporate electrical measurements into the monitoring system when suitably configured.
Product Technical Information ↗Product photographs and technical details are sourced from official AKCP product pages. Compatibility, options and licenses should be verified before deployment.
Share your project and technical requirements.