AKCP-BASED ENVIRONMENTAL MONITORING · TEKNOANS
AKCP · ENVIRONMENTAL SENSORS

Air Pollution and Pressure Sensor

The AKCP AQX4 four-in-one environmental sensor monitors air pollution index, temperature, humidity and static air pressure in one compact device.

AKCP AQX4 Hava Kirliliği ve Basınç Sensörü
Four-in-OnePollution, temperature, humidity and pressure
0–100%Air pollution level
300–1100 hPaStatic air pressure
−40…+85 °CTemperature Measurement Range
0–100% RHRelative Humidity Measurement
±0,05 hPaRelative pressure accuracy
30 metreMaximum Cable Length
AQX4Four measurements in one compact housing

Monitor Air Pollution, Temperature, Humidity and Pressure Together

The AKCP AQX4 combines four environmental measurements in a single device: air pollution index, temperature, relative humidity and static air pressure. It provides compact environmental monitoring for data centres, technical rooms, offices and industrial facilities.

The air pollution level is evaluated from gas resistance on a scale of %0–%100 A rising value over time indicates deteriorating air quality and can be used to trigger threshold-based alarms in the AKCP platform.

Static and Differential Pressure

Static pressure measurements help assess airflow supply and fan operating conditions, particularly in data centres. Delta-P can be calculated from the difference between two AQX4 pressure readings to identify unusual pressure differences across filters or passageways.

Centralised Monitoring

Measurements can be monitored and logged over the network through sensorProbe+, with alarms triggered at configured thresholds. This allows the same sensor to monitor conditions affecting both occupants and IT equipment.

Technical Specifications

Air Pollution (Gas Sensor)
Output Metric
Air pollution level (%)
Measurement Range
%0–100
Clean Air (0%)
Gas resistance ≥ 50 kΩ
Normal – Warning (%0–65)
50 kΩ > gas resistance > 18 kΩ
Warning – Critical (%65–85)
18 kΩ ≥ gas resistance > 5 kΩ
Critical – Maximum (%85–100)
5 kΩ ≥ gas resistance > 1.5 kΩ
Maximum Pollution (100%)
Gas resistance ≤ 1.5 kΩ
Air Pressure
Measurement Range
300–1100 hPa
Absolute Accuracy
±0,5 hPa
Relative Accuracy
±0,05 hPa
Temperature
Measurement Range
−40 °C to +85 °C
Measurement Resolution
Increments of 0.1 °C (0.2 °F)
Accuracy
±0.5 °C (at 25 °C)
Humidity
Measurement Range
%0–100 RH
Accuracy
±3% RH (typical)
Measurement Resolution
Increments of 1% RH
Hardware Features
Maximum Cable Length
30 m (100 ft). Standard fixed cable: 4.6 m (15 ft); custom lengths available.
Number of Sensors
4
AKCP Technical Datasheet (PDF)